Syroc® centrifugal process pumps
EN 733
Syroc® SHP end-suction pumps to EN 733
Single-stage, back-pull-out end-suction pumps for clean or slightly contaminated, low-viscosity liquids. DN 32 to DN 250, supplied as bare-shaft pump or as a complete unit with motor.

Technical data
| Discharge flange | DN 32 … DN 250 |
|---|---|
| Capacity | up to 1200 m³/h |
| Head | up to 160 m |
| Speed | up to 3600 rpm |
| Design temperature | −10 to +140 °C |
| Casing pressure (Pmax) | 10 bar (16 bar) |
| Sizes | 29 EN 733 basic sizes + 17 additional sizes |
Pmax = suction pressure + shut-off head. Contact Vaikon for higher capacity and head values. The pump material depends on the liquid, temperature and pressure.
Design features
- Horizontal, radially split volute casing; single-stage end-suction pump with closed impeller
- Dimensions to EN 733; complies with EU 547/2012
- Suction and discharge flanges to EN 1092-2 / PN 16; ANSI/ASME flanges on request
- Back-pull-out design: bearing assembly, impeller and casing cover come out without removing the volute casing from the piping
- All impellers balanced dynamically or statically to ISO 1940 grade 6.3
- Axial thrust balanced by balancing holes in the impeller
- Wear ring and/or shaft sleeve on request
- Maintenance-free, lifetime grease-lubricated ball bearings as standard; oil lubrication or re-greasable bearings on request
Handled liquids
Clean or slightly contaminated, low-viscosity liquids without solid and fibrous particles.
Shaft sealing
- Soft-packed stuffing box as standard
- Mechanical seal on request; the pump shaft is then always stainless steel
Performance range
Head against capacity per size, at 1450 and 2900 rpm. Size codes give discharge DN × nominal impeller diameter.
Send us your flow, head and liquid: we select the size, impeller diameter, material and seal for your duty point.

Pump designation
How a Syroc® SHP type code is built up, position by position.
SHP125x100-315.D328.SS.BS.CI.II.KH.D000-BUCD09.1450
| # | Position | Example | Codes |
|---|---|---|---|
| 1 | Pump series | SHP | SHP Syroc® EN 733 pump |
| 2 | Suction size | 125 | nominal diameter of the suction flange (DN) |
| 3 | Discharge size | 100 | nominal diameter of the discharge flange (DN) |
| 4 | Frame size | 315 | nominal impeller diameter: 125 · 160 · 200 · 250 · 315 · 400 · 500 |
| 5 | Impeller diameter | D328 | D + actual (trimmed) impeller diameter in mm |
| 6 | Sealing type | SS | SS single mechanical seal · SA gland packing |
| 7 | Bearing type | BS | BS standard bearing |
| 8 | Casing material | CI | CI cast iron · CS stainless steel 316 · CM stainless steel 304 · CD duplex stainless steel |
| 9 | Impeller material | II | II cast iron · IS stainless steel 316 · IM stainless steel 304 · ID duplex stainless steel |
| 10 | Shaft material | KH | KH AISI 420 stainless steel · KS stainless steel 316 · KD duplex stainless steel |
| 11 | Discharge position | D000 | D000 0° · D090 90° · D180 180° · D270 270° |
| 12 | Mounting method | BUCD | BUCD direct drive · BUCDL direct drive, left-hand rotating · empty = bare-shaft pump |
| 13 | Motor power | 09 | motor power code (see the brochure) · 00 = motor provided by the customer |
| 14 | Pump speed | 1450 | speed in rpm, e.g. 1450 · 2900 |
A bare-shaft pump has no mounting method, motor or speed: positions 12 to 14 stay empty.
Frequently asked questions
Clean or slightly contaminated, low-viscosity liquids without solid and fibrous particles, from −10 to +140 °C depending on the material.
A soft-packed stuffing box is standard. A mechanical seal is available on request; the pump shaft is then always stainless steel.
The 29 basic sizes follow the EN 733 dimensions. The 17 additional sizes may differ from other suppliers; we check the dimensions with you.
Looking for an EN 733 pump?
Tell us your liquid, flow and head. You receive a fully specified quotation, tailored to your process.