Skip to Content

Horizontal slurry pumps

Schegler® Vigor™ horizontal slurry pumps

Heavy-duty lined slurry pump for abrasive and corrosive slurries, from wastewater to coarse sand. Discharge sizes from 25 to 450 mm (1″ to 18″), capacities up to 5,000 m³/h and heads up to 70 m. Fully interchangeable with Warman® AH pumps and spare parts.

Request a quotationFree on-site assessmentDownload brochure (PDF)

Schegler Vigor horizontal slurry pump

25–450 mm

Discharge sizes (1″ to 18″)

5,000 m³/h

Maximum capacity

70 m

Maximum head

Warman® AH

Fully interchangeable

What makes the Vigor™ different

The Vigor™ is a modular, extremely robust pump: every part of the wet end can be replaced, and the pump can be configured for each duty.

Thick replaceable liners

Interchangeable liners protect the pump casing against solids impact. Schegler® liners are among the thickest in the industry. They are available in metal and elastomer, so the pump can be adapted when the slurry changes.

Cartridge bearing assembly

Heavy-duty tapered-roller bearings, grease or oil lubricated, form one cartridge with the shaft. A labyrinth seal keeps contaminants out and grease retainers reduce lubricant consumption.

Large shaft, short overhang

A large shaft diameter and a short impeller overhang minimise shaft deflection, which reduces the load on bearings and seals.

Easy impeller adjustment

Loosen the clamp bolts and move the bearing cartridge towards the suction side with the adjusting bolt. Keeping the axial clearance small maintains efficiency and reduces wear.

Fast inspection

Loosen the cover plate bolts and remove the cover plate for direct access to the wet-end parts. Worn bearings are swapped as a complete cartridge.

Sealing to suit the duty

Gland packing, expeller seal or single or double mechanical seal, selected for the slurry and the operating conditions.

Frame sizes and motor power

Most Vigor™ sizes can be built on two frame sizes, and every frame is available with heavy-duty or extra heavy-duty bearings. This gives a wide range of motor powers for the same pump size. Overview of the frame sizes F1 to F7:

FrameWarman® frameMax. motor, heavy-duty bearingsMax. motor, extra heavy-duty bearingsVigor™ pump sizes
F1B15 kW15 kW1.5x1, 2x1.5
F2C30 kW55 kW3x2, 4x3
F3D60 kW110 kW4x3, 6x4
F4E120 kW225 kW6x4, 8x6
F5F260 kW425 kW8x6; larger sizes on request
F6G600 kW900 kWLarger sizes on request
F7H1,400 kW1,400 kWLarger sizes on request

Maximum motor power per frame according to the Schegler® frame size data. The actual limit also depends on the pump size, speed and configuration.

Drive configurations and discharge positions

The drive depends on the available space, the slurry, the capacity and the maintenance requirements. The discharge can be rotated in eight positions in steps of 45°, without modifying the pump; D000 is standard.

CD – Direct drive

When the speed is fixed and enough floor space is available. Low failure rate, no speed loss and high efficiency.

CT – Top mount

Belt drive when the speed can be variable and floor space is limited.

CS – Sliding base top mount

The benefits of CT, with extra serviceability.

CB – Back top mount

When the selected motor is too large to be top-mounted.

CL / CR – Left or right side mount

Belt drive when the speed can be variable and the space above the pump is limited.

Discharge positions

Rotating the casing can extend wear life, for example in cyclone feed duties, or allow drainage without slurry blocking the impeller.

Wear materials

Impellers and liners are available in a wide range of metals and elastomers. The choice depends on the solid size, specific gravity, hardness and shape, the pH and chemicals, the slurry temperature and the impeller speed. Elastomers deform elastically and resist erosion by fine particles; metals handle higher speeds and larger, sharper particles.

Metals: high chrome, ultra-high chrome, hyper chrome, Hastelloy, stainless steel, duplex stainless steel, cast iron. Elastomers: natural rubber, reinforced rubber, butyl rubber, neoprene, polyurethane, Hypalon®. More materials on request.

Read more about Schegler® material 420 (high-chrome molybdenum)

Vigor™ sizes and specifications

Bareshaft data from the Schegler® specification sheets for the standard high-chrome and natural-rubber versions. Sizes 10x8 to 20x18 are available on request.

SizeFrameLiner and impellerImpellerSolids passage (mm)Max. speed (rpm)Max. motor (kW)Bareshaft weight (kg)Specification sheet
Vigor™ 1.5x1F1High chrome5-vane open144,4001590PDF
Vigor™ 1.5x1F1Natural rubber3-vane open203,2001575PDF
Vigor™ 2x1.5F1High chrome5-vane open193,20015100PDF
Vigor™ 2x1.5F1Natural rubber5-vane open162,6001585PDF
Vigor™ 3x2F2High chrome5-vane closed253,17030200PDF
Vigor™ 3x2F2Natural rubber5-vane open212,30030160PDF
Vigor™ 4x3F2High chrome5-vane closed362,75030300PDF
Vigor™ 4x3F2Natural rubber5-vane closed281,80030230PDF
Vigor™ 6x4F3High chrome5-vane closed511,80060660PDF
Vigor™ 6x4F3Natural rubber5-vane closed331,35060420PDF
Vigor™ 8x6F4High chrome5-vane closed631,5001201,510PDF
Vigor™ 8x6F4Natural rubber5-vane closed591,000120980PDF

Data from the specification sheets per configuration. Other configurations, such as other materials, seals or frames, change these values.

Vigor™ family curves

Schegler Vigor family curves: total head versus capacity per pump size

The curves show pump performance with clean water and are only intended for a first selection. We select the right size and speed for your slurry.

Frequently asked questions

For abrasive or corrosive liquids with particles, from wastewater to abrasive slurries: for example cyclone feed, filter press feed, wastewater transfer and hot, acidic process slurries.

Discharge sizes from 25 to 450 mm (1″ to 18″), capacities up to 5,000 m³/h and heads up to 70 m. Specification sheets are available for sizes 1.5x1 to 8x6; larger sizes on request.

Yes. The Schegler® Vigor™ is fully interchangeable with Warman® AH pumps and spare parts.

Elastomers such as natural rubber resist erosion by fine particles and are used at lower speeds. Metals such as high chrome handle higher speeds and larger, sharper particles. The choice also depends on pH, chemicals and temperature.

From 14 mm (Vigor™ 1.5x1, high chrome) to 63 mm (Vigor™ 8x6, high chrome) in the standard configurations. Other impellers give other values, such as 63 mm with a 2-vane open impeller in a Vigor™ 6x4.

Depending on the frame size (F1 to F7) and the bearing version, from 15 kW up to 1,400 kW. Most Vigor™ sizes can be built on two frame sizes, so you can choose a heavier frame for a higher motor power.

Which Vigor™ do you need?

Send us your flow rate, head and slurry data. You receive a quotation within 24 hours.